Building to the Passivhaus (Passive House) standard, for new homes and EnerPHit refurbishments
Passivhaus, also known as Passive House, is the leading international standard for comfortable, very low-energy buildings. A Passive House stays warm with very little heating, has fresh, filtered air all year round and is free of draughts, cold spots and condensation. Greenbuild builds to the Passivhaus standard across Sussex and Surrey, as principal contractor or design and build contractor, working alongside Passivhaus designers and certifiers.
The Five Passive House Principles
Excellent insulation wrapped continuously around the building
Airtightness far beyond what Building Regulations require
High-performance windows and doors, typically triple glazed
Thermal-bridge-free detailing at junctions, foundations and openings
Mechanical ventilation with heat recovery (MVHR) for constant fresh air with minimal heat loss
The Passivhaus Standard in Numbers
Space heating demand of no more than 15 kWh per m² per year, or a peak heating load of no more than 10 W/m²
Airtightness of no more than 0.6 air changes per hour at 50 Pa, proven by an on-site pressure test
Renewable primary energy demand of no more than 60 kWh per m² per year for Passivhaus Classic, with Plus and Premium classes adding renewable generation
Summer comfort, with no more than 10% of hours a year above 25°C
For refurbishments, the EnerPHit standard applies the same principles to existing buildings, with a space heating demand of no more than 25 kWh per m² per year and airtightness of no more than 1.0 air changes per hour.
Certified Passivhaus or Passivhaus Standard?
Certification by an accredited Passivhaus certifier gives independent proof that the building performs as designed, and only a certified building can be called a Passivhaus. Some clients choose to design and build to Passivhaus principles without the full certification process, for example targeting 0.6 air changes per hour. We’ll help you weigh up the cost and value of each route.
A Passive House Is Built in the Details
Passivhaus performance is won or lost on site. Airtight membranes and tapes, window installation, service penetrations and thermal bridges all need careful sequencing and checking. We plan the airtight layer and service routes in Revit and Rhino before work starts, brief every trade on why it matters, and test airtightness during the build as well as at the end, so any problems are found while they can still be fixed.
Heating, Ventilation and Renewables
Because heat demand is so low, a small heat pump can heat a Passive House and provide its hot water, while MVHR keeps the air fresh. Add solar PV and a battery, and a Passivhaus home can produce a large share of the energy it uses over a year. We design these systems in-house; see our renewables page. For more on reducing both operational and embodied carbon, see our low-carbon building page.
Passivhaus Retrofit with EnerPHit
A deep refurbishment is the right moment to bring an existing home towards Passive House performance. EnerPHit can be achieved in one go or step by step, and even where full certification isn’t the goal, its principles make a dramatic difference to comfort and running costs.
What Does a Passivhaus Cost?
Building to Passivhaus costs more than a standard specification, though the gap narrows with good design and an experienced team, and running costs are dramatically lower. Our free pre-tender estimate can price a Passivhaus specification alongside a Building Regulations specification, so you can see the difference in build cost, running costs and carbon.
Frequently Asked Questions
What is the difference between Passivhaus and Passive House?
There isn’t one. Passivhaus is the original German name and Passive House is the English translation. Both refer to the same standard, developed by the Passive House Institute.
Can you open the windows in a Passivhaus?
Yes. You can open windows whenever you like. The MVHR system simply means you don’t have to in order to get fresh air, even in winter.
Do Passive House homes overheat?
They shouldn’t. Summer comfort is part of the standard, so shading, glazing and ventilation are designed to keep temperatures comfortable. Where extra cooling is wanted, it can be designed in discreetly; see our air conditioning page.
Talk to Us About Building a Passivhaus
We typically take on projects from £500,000 across West Sussex, East Sussex and Surrey. Get in touch for a free pre-tender estimate, or call us on 01403 266885.
Let's Talk
Creating beautiful homes is our speciality. We would love to hear more about your next project, please get in touch using the form provided or, you can contact us using one of the methods below.
By continuing to use our website you agree to the use of cookies to provide you with a better online experience Accept
Manage consent
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. These cookies ensure basic functionalities and security features of the website, anonymously.
Cookie
Duration
Description
cookielawinfo-checbox-analytics
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics".
cookielawinfo-checbox-functional
11 months
The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional".
cookielawinfo-checbox-others
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other.
cookielawinfo-checkbox-necessary
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-performance
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance".
viewed_cookie_policy
11 months
The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.